51
P
A
RAMETE
R
S
4.1.4
Change the parameter setting value
4.1.5
Setting dial push
Push the setting dial (
) to display the set frequency* currently set.
* Appears when PU operation mode or external/PU combined operation mode 1 is selected (
Pr. 79
="3").
Changing
example
Change the
Pr. 1 Maximum frequency
setting.
Operation Display
1.
Screen at powering on
The monitor display appears.
2.
Press
to choose the PU operation mode.
PU indication is lit.
3.
Press
to choose the parameter setting
mode.
PRM indication is lit.
(The parameter number read previously
appears.)
4.
Turn
until
(Pr. 1)
appears.
5.
Press
to read the currently set value.
"
"(120.0Hz (initial value) appears.
6.
Turn
to change the set value to
"
" (50.00Hz).
7.
Press
to set.
Flicker...Parameter setting complete!!
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Press
twice to return the monitor to frequency monitor.
REMARKS
is displayed...Why?
appears .................... Write disable error
appears .................... Write error during operation
appears .................... Calibration error
appears .................... Mode designation error
(For details, refer to
page 246
.)
The number of digits displayed on the operation panel is four. Only the upper four digits of values can be displayed and set. If the
values to be displayed have five digits or more including decimal places, the fifth or later numerals can not be displayed nor set.
(Example) For
Pr. 1
When 50Hz is set, 50.00 is displayed.
When 120Hz is set, 120.0 is displayed and second decimal place is not displayed nor set.
to
Содержание FR-D700 Series
Страница 11: ...VII MEMO ...
Страница 23: ...12 MEMO ...
Страница 57: ...46 MEMO ...
Страница 262: ...258 MEMO ...
Страница 276: ...272 MEMO ...
Страница 283: ...279 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 287: ...283 MEMO ...
Страница 289: ......