Selection of operation mode and operation location
(1) Operation mode basics
The operation mode specifies the souce of the start command and the frequency command for the inverter.
Select the "external operation mode" when the start command and the frequency command are applied from a
potentiometer, switches, etc. which are provided externally and connecting them to the control terminals. Select "PU
operation mode" when the commands are applied using the operation panel or parameter unit (FR-PU04/FR-PU07). Select
the "network operation mode (NET operation mode)" when the commands are applied from the RS-485 communication
with the PU connector.
The operation mode can be selected from the operation panel or with the communication instruction code.
REMARKS
Either "3" or "4" may be set to select the PU/external combined mode.
for details.
The stop function (PU stop selection) activated by pressing
of the operation panel and parameter unit (FR-PU04/FR-
PU07) is valid even in other than the PU operation mode in the initial setting.
(
Refer to Pr. 75 Reset selection/disconnected PU detection/PU stop selection (page
153))
External
operation mode
Personal computer
Personal computer
FR-PU07
PLC
Potentiometer
Switch
Inverter
GOT
PU connector
1
2
3
4
5 6
7
8
9
10
PU operation mode
Network
operation mode
PU operation mode
Control terminal
Operation panel