217
Special operation and frequency control
(2) Dancer control overview
Performs dancer control by setting 40 to 43 in
Pr. 128 PID action selection.
The main speed command is the speed command of
each operation mode (external, PU, communication). Performs PID control by the position detection signal of the dancer
roller, then the result is added to the main speed command. For acceleration/deceleration of the main speed, set the
acceleration time in
Pr. 44 Second acceleration/deceleration time
in
Pr. 45 Second deceleration time
.
* Set 0s normally to
Pr. 7 Acceleration time
and
Pr.8 Deceleration time
. When the
Pr. 7 and Pr. 8
setting is large, response of dancer control during acceleration/
deceleration is slow.
(3) Connection diagram
Source logic
Pr. 128 =
41
Pr. 182 =
14
Pr. 190 =
15
Pr. 192 =
16
∗1
The main speed command differs according to each operation mode (external, PU, communication)
∗2
The used output signal terminal changes depending on the
Pr. 190, Pr. 192 (output terminal selection)
setting.
∗3
The used input signal terminal changes depending on the
Pr. 178 to Pr. 182(input terminal selection)
setting.
STF
PID adding value
Main speed
ON
Output frequency
Time
Output frequency
Power supply
MCCB
Inverter
Forward rotation
Reverse rotation
PID control selection
Main speed commnad
setting potentiometer
*1
R/L1
S/L2
T/L3
STF
STR
RH(X14)
*3
PC
10
2
5
4
U
V
W
*2
(FUP)RUN
SE
Motor
IM
Upper limit
Output signal common
Feedback value of
dancer roll position
Содержание FR-D700 Series
Страница 11: ...VII MEMO ...
Страница 23: ...12 MEMO ...
Страница 57: ...46 MEMO ...
Страница 262: ...258 MEMO ...
Страница 276: ...272 MEMO ...
Страница 283: ...279 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 287: ...283 MEMO ...
Страница 289: ......