![Mitsubishi Electric FR-D700 Series Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/mitsubishi-electric/fr-d700-series/fr-d700-series_instruction-manual_239211068.webp)
Parameter list
Parameter list
62
Parameter List
—
564
Operating time carrying-over times
(0 to 65535)
1
0
564
40
C0
5
×
×
×
—
571
Holding time at a start
0 to 10s, 9999
0.1s
9999
571
47
C7
5
PID
operation
575
Output interruption detection time
0 to 3600s, 9999
0.1s
1s
575
4B
CB
5
576
Output interruption detection level
0 to 400Hz
0.01Hz
0Hz
576
4C
CC
5
577
Output interruption cancel level
900 to 1100%
0.1%
1000%
577
4D
CD
5
Tr
av
er
se
592
Traverse function selection
0, 1, 2
1
0
592
5C
DC
5
593
Maximum amplitude amount
0 to 25%
0.1%
10%
593
5D
DD
5
594
Amplitude compensation amount
during deceleration
0 to 50%
0.1%
10%
594
5E
DE
5
595
Amplitude compensation amount
during acceleration
0 to 50%
0.1%
10%
595
5F
DF
5
596
Amplitude acceleration time
0.1 to 3600s
0.1s
5s
596
60
E0
5
597
Amplitude deceleration time
0.1 to 3600s
0.1s
5s
597
61
E1
5
—
611
Acceleration time at a restart
0 to 3600s, 9999
0.1s
9999
611
0B
8B
6
—
653
Speed smoothing control
0 to 200%
0.1%
0
653
35
B5
6
—
665
Regeneration avoidance frequency
gain
0 to 200%
0.1%
100
665
41
C1
6
Prote
ctiv
e
functions
872
∗8
Input phase loss protection selection
0, 1
1
1
872
48
C8
8
R
egenera
tion avoidance
function
882
Regeneration avoidance operation
selection
0, 1, 2
1
0
882
52
D2
8
883
Regeneration avoidance operation
level
300 to 800V
0.1V
400VDC/
780VDC
∗6
883
53
D3
8
885
Regeneration avoidance compensation
frequency limit value
0 to 10Hz, 9999
0.01Hz
6Hz
885
55
D5
8
886
Regeneration avoidance voltage gain
0 to 200%
0.1%
100%
886
56
D6
8
Fr
ee
pa
ra
m
et
e
r
888
Free parameter 1
0 to 9999
1
9999
888
58
D8
8
×
×
889
Free parameter 2
0 to 9999
1
9999
889
59
D9
8
×
×
—
891
Cumulative power monitor digit shifted
times
0 to 4, 9999
1
9999
891
5B
D8
8
C
alibration p
arameter
s
C1
(901)
∗5
AM terminal calibration
—
—
—
C1
(901)
5D
DD
1
×
C2
(902)
∗5
Terminal 2 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
C2
(902)
5E
DE
1
×
C3
(902)
∗5
Terminal 2 frequency setting bias
0 to 300%
0.1%
0%
C3
(902)
5E
DE
1
×
125
(903)
∗5
Terminal 2 frequency setting gain
frequency
0 to 400Hz
0.01Hz
50Hz
125
(903)
5F
DF
1
×
C4
(903)
∗5
Terminal 2 frequency setting gain
0 to 300%
0.1%
100%
C4
(903)
5F
DF
1
×
C5
(904)
∗5
Terminal 4 frequency setting bias
frequency
0 to 400Hz
0.01Hz
0Hz
C5
(904)
60
E0
1
×
C6
(904)
∗5
Terminal 4 frequency setting bias
0 to 300%
0.1%
20%
C6
(904)
60
E0
1
×
126
(905)
∗5
Terminal 4 frequency setting gain
frequency
0 to 400Hz
0.01Hz
50Hz
126
(905)
61
E1
1
×
C7
(905)
∗5
Terminal 4 frequency setting gain
0 to 300%
0.1%
100%
C7
(905)
61
E1
1
×
—
C22 to C25
(922 to 923)
Parameter for manufacturer setting. Do not set.
C22 to C25
(922 to 923)
Parameter for manufacturer setting. Do not set.
PU
990
PU buzzer control
0, 1
1
1
990
5A
DA
9
991
PU contrast adjustment
0 to 63
1
58
991
5B
DB
9
×
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read
Write
Extended
Copy
Clear
All clear
V/F
V/F
V/F
GP MFVC
GP MFVC
GP MFVC
Содержание FR-D700 Series
Страница 11: ...VII MEMO ...
Страница 23: ...12 MEMO ...
Страница 57: ...46 MEMO ...
Страница 262: ...258 MEMO ...
Страница 276: ...272 MEMO ...
Страница 283: ...279 APPENDIX This chapter provides the APPENDIX of this product Always read the instructions before using the equipment ...
Страница 287: ...283 MEMO ...
Страница 289: ......