124
Calibrating the Kaleido-X
5
4. Expand the appropriate input card, then one of its embedded audio elements, and select Zero VU.
Zero VU audio selection
5. In the Properties pane, set the reference level to the appropriate value (in dBFS), using the Zero VU
slider, under Calibration. Alternatively, type the value directly in the Zero VU box.
Zero VU reference level selection
6. Click Apply to all to apply the chosen Zero VU reference value throughout the system.
7. On the File menu, click Save. Alternatively, click the Save button on the toolbar.
Calibrating Zero VU Reference Level for an ABT Audio Source
To calibrate an ABT audio source:
1. Click the System tab in the main window.
Содержание Kaleido-X (4RU)
Страница 4: ...iv ...
Страница 15: ...Kaleido X 4RU SystemBlock Diagram 5 Kaleido X 4RU System Block Diagram Kaleido X 4RU systemblockdiagram ...
Страница 20: ...10 GettingStarted 1 4 Connect one or more video sources to the frame Kaleido X 7RU cablingdiagram ...
Страница 54: ...44 GettingStarted 1 ...
Страница 58: ...48 New Features 2 ...
Страница 88: ...78 Operation of the Monitor Wall 3 ...
Страница 120: ...110 Calibratingthe Kaleido X 5 CalibratingMetadata Holding Time 134 CalibratingGPI Lines 136 ...
Страница 160: ...150 Configuring Alarms 6 ...
Страница 168: ...158 Creating Channels 7 ...
Страница 252: ...242 Creating Layouts 9 ...
Страница 264: ...254 Creating Actions 10 ...
Страница 358: ...348 Third Party Devices 13 ...
Страница 360: ......
Страница 362: ...352 Using the Serial to TCP IP Dispatcher 15 ...
Страница 373: ...Servicing 363 The Technical Support contact information page appears TechnicalSupportpage 5 Click System snapshot ...
Страница 380: ...370 Administration andServicing 16 ...
Страница 382: ......
Страница 388: ...378 Index Zooming59 ...