4.
INSTALLAZIONE • INSTALLATION
ENGLISH
ITALIANO
–
60 –
4.3.9 Protection - Installation
The protections must always be
mounted and be positioned in
such as way as to completely
cover the tools.
Saw guard (fig. 13)
– Lift the saw assembly by means
of the knob A after loosening
the knob B.
– Fit in the protection C and tighten
the handle E.
Arm saw protection fig. 14
– Fit the arm A to the work table.
– Introduce the protection support
B into arm A and fasten it
through screw C.
– Fit protection E on support L
through screws G.
– Lower the guard into place on
the saw table and check:
- that the saw blade is flush with
the wood F ;
- that the guard is parallel to the
table and centred with respect
to the blade.
– Loosen the screws C and G to
adjust the correct position of the
guard.
– Adjust the stop screw H in such
a way that the guard does not
rise above the saw blade.
4.3.9 Protezioni -
Installazione
Le protezioni devono sempre
essere montate,e devono
essere posizionate in modo da
coprire al massimo gli utensili.
Protezione sega (fig. 13)
– Sollevare il gruppo sega me-
diante il pomello A previo
allentamento del pomello B.
– Inserire la protezione C serran-
do la maniglia E.
Protezione sega a braccio fig.14
– Fissare il braccio A al piano di
lavoro.
– Inserire il supporto protezione B
nel braccio A e bloccarlo me-
diante la vite C.
– Montare la protezione E sul sup-
porto L mediante le viti G.
– Abbassare la protezione in bat-
tuta sul piano sega e verificare:
- che la lama sega sia a filo con
il legno F ;
- che la protezione sia parallela
al piano, e centrata rispetto le
lame.
– Allentare le viti C e G per regi-
strare la corretta posizione della
protezione.
– Registrare la vite di battuta H in
modo che la protezione non si
alzi al di sopra della lama sega.
A
H
G
F
C
B
A
L
21_090_0.tif
14
E
5
10
15
20
25
30
35
40
45
45
21_050_0.CGM / 021_009_2.tif
A
B
13
E
C
Содержание LAB 300 N