3-34
Detect operation
1
Scan in the B direction (plus direction)
to detect the line.
• The buzzer sounds when the line is detected. If
the line is not detected, the buzzer does not
sound.
2
Scan in the B direction (minus
direction) to detect the line.
3
Scan in the A direction (plus direction)
to detect the line.
4
Scan in the A direction (minus
direction) to detect the line.
5
Follow the Steps 1 to 4, and confirm if
the buzzer sounds 4 times.
• When the detection behavior completes
successfully, the buzzer sounds 4 times.
• If the plotter failed to detect the line, perform "Adjust
the sensitivity (light intensity) of the mark sensor
LED (automatically)"
(
P.3-36
)
.
• If the plotter cannot detect the line successfully
even after you adjusted the sensitivity, you must verify the registration conditions and
contact our sales branches (for service call).
Minus
direction
Plus
direction
Mark length
Scan in the A direction