20
Pellerin Milnor Corporation
Table 4.
DIP Switch Settings for Industry Configurations
Industry
Configuration
Switch Settings
S1
S2
S3
S4
S5
S6
S7
S8
Correctional Facilities
ON
ON
ON
ON
This
switch is
not used
on V_J
and F_J
models.
On pre-
vents/Off
allows
skipping
steps.*
These switches
are not used in
these models.
Hotels and Motels
OFF
ON
ON
ON
Athletic Laundries
ON
OFF
ON
ON
Healthcare Facilities
OFF
OFF
ON
ON
Restaurants
ON
ON
OFF
ON
Commercial
Laundries
OFF
ON
OFF
ON
Shirt Laundries
ON
OFF
OFF
ON
Offshore Laundries
OFF
OFF
OFF
ON
Gear Guardian
®
ON
ON
ON
OFF
* Setting S6 off enables the operator to cancel any step in progress except a drain before an
extract.
NOTE:
The Gear Guardian
®
configuration is available with machine software
WUT5XGGA or WUMWRXGG only.
BNCJHP02 / 2020434
BNCJHP02
0000192149
D.2
10/21/20 3:52 PM
Released
2.3
Programming the E-P Plus
®
Controller
BNCJHP02.C01 0000192163 C.2 D.2 B.3 1/2/20 1:16 PM Released
The microprocessor controller used in this washer extractor operates in three modes, depending
on whether the machine is processing goods (the
Run mode
or
Formula
menu), being pro-
grammed with operating characteristics to be used when a wash formula is started (the
Program
mode), or being tested (the
Manual
or
Test
mode). This document describes the available opera-
tor actions and display feedback in the
Program
mode.
The
Program
mode is accessible only when the
Run/Program keyswitch
is set to the
Program
position (
), as described below. From the
Program
menu, there are four options available:
•
Option 0: OK TURN KEY TO RUN (detailed in
2.3.2: Return to Run Mode (Option 0), page
)
•
Option 1: ADD/CHANGE FORMULA (detailed in
2.3.3: How to Add or Change a Formula
•
Option 2: CONFIGURE (Detailed configure instructions are provided elsewhere in the man-
ual. See the table of contents.)
•
Option 3: STANDARD FORMULAS
•
Option 4: DATA TRANSFER
Each of these options is described in detail in this document. For information on how to start the
machine and run a formula, see the appropriate section listed in the table of contents of this
manual.