Pellerin Milnor Corporation
19
The Milnor
®
factory sets each washer-extractor controller for the specified operation. You can
change the DIP switches on the processor board to change the machine configuration for a differ-
ent operation. This document describes how to set the DIP switches. A different operation name-
plate is necessary on some models. Get operation nameplates from your dealer or the Milnor
®
parts department.
To change industry configuration, turn the machine
off
. Then lock off and tag out power to the
machine at the wall disconnect before accessing the processor board.
WARNING:
Electrified parts inside —
can shock or electrocute you.
�
Turn off and lockout/tagout electric power before you open an electri-
cal cabinet.
The microprocessor board holds the DIP switches as shown in the following figure also shows
the
on
and
off
positions. Set the switches to the desired positions according to the following table.
Turn the machine
on
; the display will show the current configuration.
CAUTION:
Risk of improper configuration —
On some machines, the processor
board is installed in the control box so that the labels printed on the DIP
switch appear inverted.
�
Do not assume that the switch is right side up. Always reference the la-
bels (
OFF
,
ON
,
1
,
2
, etc.)
printed on the switch
when setting DIP
switches.
Figure 7.
Location of DIP Switches
Processor Board
Legend
A.
DIP switch
B.
Board identification area
1.
OFF
2.
ON
3.
ON
4.
OFF
DIP Switch (Partial View)