Pellerin Milnor Corporation
35
Display or Action
Explanation
03 SPD
D
E
01
X
Select a drain type for this bath step. This decision controls
whether the drain valve opens or remains closed when this bath
step ends, and how the basket rotates (if at all) while the machine
is filling and draining. Some of the selections below are valid only
if the step following this bath is another bath step. For example,
programming this decision as
1=Two way wash speed
is not al-
lowed before an extract step because the goods would not be
evenly distributed around the basket when the machine acceler-
ated to extract speed.
NOTICE:
Selected drain type may change automatically—The controller requires that
the basket always accelerate to drain speed before advancing to extract speed, even if a
stop or bath-speed drain type is programmed.
•
Standard
and
stop at fill
drain types are valid for bath steps followed by any other type of
step.
•
Two-way wash speed, do not drain
, and
stop at drain
drain types will automatically change
to a
standard
drain when an extract is programmed as the next step.
•
A stop at fill
and
drain
drain type will automatically change to a
stop at fill
drain type when
an extract is programmed as the next step.
Table 7.
Summary of Drain Type Choices
Drain
Type
Help Screen
Description
Basket Motion
Drain Valve
During Fill Phase
During Drain Phase
0
Standard
set by Type of Step
decision for this step
standard drain speed
opens after distribution
1
2-way wash
(see Note A
below)
set by Type of Step
decision for this step
reversing at wash
speed
opens after programmed
step time
2
Do not drain
(see Note A
below)
set by Type of Step
decision for this step
none—following bath
determines basket
rotation
does not open
3
Stop at fill
stopped until desired
level is achieved
rotates clockwise at
standard drain speed
opens after distribution
4
Stop at drain
(see Note A
below)
set by Type of Step
decision for this step
stopped
opens after programmed
step time
5
Stop fill & dr
(see Note A
below)
stopped until desired
level is achieved
stopped
opens after programmed
step time
6
RinSave
®
(see Note B
below)
set by Type of Step
decision for this step
advanced drain se-
quence (described
above)
opens 10-15 seconds
after bath time ends
Содержание E-P Plus
Страница 2: ......