78
Pellerin Milnor Corporation
5.1.6
Option Outputs (E-P Plus
®
Models Only)
BNCJUF01.C09 0000190124 C.2 C.3 B.3 1/2/20 1:16 PM Released
The 188 E-P Plus
®
processor board used in F_J, H_J, X_J, and V_J models includes the option
output relays as well as the standard output relays directly on the board. All 22 of the output re-
lays on the 188 processor board are identical.
5.1.7
Temperature Probe (E-P Plus
®
Models Only)
BNCJUF01.C10 0000190171 C.2 C.3 B.3 1/2/20 1:16 PM Released
A thermistor temperature probe is provided in the machine sump if the machine is equipped for
optional temperature control. This probe is a resistor that changes value according to temperature.
5.1.8
Pressure Sensor (E-P Plus
®
Models Only)
BNCJUF01.C11 0000190170 C.2 C.3 1/2/20 1:16 PM Released
The 188 E-P Plus
®
processor board contains a pressure transducer unit mounted directly to the
board. This transducer produces a very small voltage (about 0.085 millivolt per inch of water) that
increases as the water level in the basket rises. For E-P Plus
®
models, detailed information on the
Pressure Transducer Circuit is provided. See table of contents.
BNUUUP01 / 2018302
BNUUUP01
0000196579
A.4
1/2/20 2:14 PM
Released
5.2
Serial Memory Storage Device Applications
BNUUUP01.C01 0000196602 C.2 A.4 A.5 1/2/20 2:14 PM Released
A serial memory storage device similar to one shown below can be used to store machine config-
uration and formula data for most current models of Milnor
®
machines. DIP switches inside the
storage device allow you to configure the device to accept data from several different machine
types and software versions. Use this document to determine the proper DIP switch setting for
your machine. After verifying the switch settings, label the storage device with the date, machine
name, and serial number to avoid confusion when the device is needed to restore data to a
machine.