44
Pellerin Milnor Corporation
additional programming decision available for bath steps, allow-
ing draining to a reuse tank for use in later baths, for example.
RinSave Option ?
0=NO, 1=YES
0
RinSave
®
is an option available on certain rigid-mount machine
models with software WUV7J1B/2300K and later. When this
option is enabled, a value of 6 can be programmed into decision
D (drain type).
MACHINE TYPE ?
3=3022V6J
3
Select the appropriate machine type as stated on the machine
nameplate. One of the following two lists will appear, depending
on the software version your machine uses.
version WUV7J1B:
version WUH7JA:
0 = 30015T5J
1 = 30015V7J
2 = 30022T5J
3 = 30022V6J
4 = 36026V5J
5 = 36021/36026V7J
6 = 42026/42030V6J
7 = 36026X8J
8 = 42026/42032X7J
9 = 48040F7J/B
10 = MWF100J7
0 = 30022VRJ
1 = 30022X8J
2 = MWF27J
CAUTION:
Avoid machine malfunction —
Improper configuration will cause ma-
chines to malfunction.
�
Misconfigured V_J models will only run at one wash speed and one extract speed.
Display or Action
Explanation
N/O Drain ?
0=NO 1=YES
1
Select
1=Yes
only if this machine is equipped with a normally-
opened drain valve (usually the drain valve to the sewer).
The following two configure decisions are available on F_J and V_J models with software
WUV7J1B/2200L and later and H_J and X_J models using software WUH7JA/2200G and later.
The decisions allow the person programming the machine to program alternate
ON
and
OFF
times for basket rotation during wash steps. The values configured here are used only when a
wash step is programmed with a basket speed (
SPD
decision) of 2 or 3.
NOTICE:
Avoid unexpected values—Because of the nature of the memory used to store
configure decisions, the values for alternate ON time and alternate OFF time may range
randomly between three and 255 seconds before the values are configured the first time.
This will not damage the machine, but might cause unexpected operation if wash speed 2
or 3 is programmed.
•
Understand the consequences of all programming decisions before creating new formulas or
changing the existing default formulas.
Содержание E-P Plus