58
Pellerin Milnor Corporation
A168 indicates that the current achieved temperature is 168 de-
grees. Temperature is displayed only if machine is equipped with
and configured for temperature control.
D170 indicates that the desired temperature for this step is 170 de-
grees. Temperature is displayed only if the machine is equipped
with and configured for temperature control.
LEV 2 indicates that the bath level achieved is Level 2.
SPD 0
LEV 2
SPD 0 indicates the bath speed (either 0 or 1) for this step.
WAIT FOR LEVEL 2 H indicates that Level 2 is programmed for
this step, but is not yet achieved. The H indicates that the hot
water valve is open; C indicates cold water, and 3 indicates extra
water.
CHEM 03 is displayed when Chemical 03 is being injected. The
number for each chemical (up to five may be connected) is dis-
played as the chemical is injected. See also
for information about the chemical flush
valve.
FINAL EXTRACT indicates that the step in progress is the final
step of the wash formula.
3.1.5
How to Shorten, Terminate, or Suspend a Running
Formula
BNCJHO01.C07 0000182502 C.2 B.3 A.3 1/2/20 1:16 PM Released
Display or Action
Explanation
Cancels a step. Advances the step timer to zero for any bath, a
drain not followed by an extract, or any extract in progress. The
next step begins automatically.
This operation is possible only if DIP switch 6 on the processor
board is in the
off
position, allowing the cancelling of steps.
Cancels the current formula and returns the machine to the Run
Formula
display.
RUN FORMULA
This is the
Run Formula
display. The door interlock delay, de-
scribed in
, must expire
before the door can be opened.
00
OK TO POWER OFF
3.1.6
How to Restart after Power Loss
BNCJHO01.C08 0000182501 C.2 B.3 A.3 1/2/20 1:16 PM Released
The E-P Plus control remembers the formula and step it was executing if power fails or if the wall
disconnect is turned off while the machine is operating in automatic mode.