Pellerin Milnor Corporation
71
Figure 11.
Pressure Transducer Component Identification
“Rev. E” Processor Board
Legend
A...
Pressure transducer
B...
Instrumentation amplifier
C...
Edge of processor board
1...
Pin 1 of each component
2...
Pin 2
3...
Pin 3
4...
Pin 4
5...
Pin 5
6...
Pin 6
“Rev. L” Processor Board
4.1.7
Viewing Inputs and Outputs During Operation
BNCJHT01.R06 0000191877 C.2 F.3 B.3 1/2/20 1:16 PM Released
While the machine must be idle to actuate outputs, inputs and outputs can be viewed (but not
turned on or off) while the machine is operating.
Display or Action
Explanation
23:04
F02S01
02:37
L=A1/D1
Hot Wash
This is a typical display while the machine is running a formula.
displays the inputs. A plus sign (+) indicates the input is
grounded, while a minus sign (–) indicates the input is not
grounded.
ABCDEFGHIJK
+++--------
typical display of input status while the machine is running. Refer
to
Table 12: E-P Plus Inputs, page 63
to determine which input is
represented by each character on the display.
displays the first 11 outputs (Page 0). A plus sign (+) indicates the
output is actuated, while a minus sign (–) indicates the output is
turned off.