Pellerin Milnor Corporation
57
Table 11
Coast Times (in seconds) at Program End or Termination (cont'd.)
Model
Door Unlock
Delay (DUD)
Bath
Low Extract
High
Extract
Power-up
Delay
36026V7J
25
DUD
75 + DUD
85 + DUD
100
42026V6J
25
DUD
75 + DUD
85 + DUD
100
36026X8J
25
DUD
100 + DUD
150 + DUD
150
42026/42032X7J
25
DUD
100 + DUD
150 + DUD
150
48040F7J/B
25
DUD
100 + DUD
200 + DUD
160
Note:
Coast time when an extract step ends normally does not include the door unlock delay.
NOTE:
Depending on the
How to End code
, the controller will describe how the cycle
is ending and instruct the operator to press
to escape this step in the cycle.
Display or Action
Explanation
UNLOCKING THE DOOR
PLEASE WAIT
display during the last 15 seconds of coast, or during the entire
coast time if the formula was manually terminated.
WAITING TO UNLOAD
U
At the end of the coast time, the operator alarm sounds.
Silences the operator alarm. The door unlocks, and the machine
may be unloaded.
3.1.4
The Display During Automatic Operation
BNCJHO01.C06 0000182503 C.2 B.3 1/2/20 1:16 PM Released
Display or Action
Explanation
23:04
F02S01
02:37
TEMP A168/D170 LEV 1
These two displays alternate during normal operation.
23:04 STEP 01
02:37
TEMP A168/D170 SPD 0
23:04
F02S01
02:37
23:04 is the time remaining in the formula.
F02S01 indicates that the current formula is 02 (F02) and the cur-
rent step is 01 (S01).
02:37 is the time remaining in this step.
23:04
STEP01
02:37
STEP01 is the current step
EXTRACT indicates that the machine is currently executing an
extract.
TIMEHALT indicates that the timer is stopped while a chemical is
being injected. The chemical supplier must connect equipment for
this option.
TEMP A168/D170 LEV 2
Temperature in this machine is measured in degrees Fahrenheit or
Celsius, according to machine configuration.