Pellerin Milnor Corporation
75
valve on cooldown inlet. Cooldown will continue until the desired
temperature is achieved, when the error will automatically clear.
TOO LONG TO DRAIN
The machine did not drain properly in the allotted drain time. This
self-correcting error will clear when the water level in the basket
is low enough to begin the next operation. The drain time before
this message appears is controlled by a configure decision. De-
tailed configure instructions can be found elsewhere in the man-
ual. See table of contents.
CHECK PROBE
This error message indicates that the resistance of the temperature
probe is outside the specified range. Test the probe by disconnect-
ing the probe leads from the processor board and checking the re-
sistance with an accurate digital ohmmeter. Resistance between
the two leads must be between 2K and 35K Ohms. Resistance be-
tween each lead and ground must be infinite.
EXTERNAL FAULT
On most machines, this error indicates that the programmed
chemical injection failed, usually because the chemical supply
system is empty. When chemicals are added and can be injected,
this error clears automatically, allowing operation to resume.
On 48040F7J/F7B models, this error indicates that the bearing air
pressure is below the minimum required to help protect the bear-
ing from water contamination.
BRAKE PRESS. FAULT
This error appears only on machine models equipped with a cylin-
der brake. The message indicates that the brake is engaged when
it should be disengaged. This is usually because the machine is
not receiving sufficient air pressure to open the normally-closed
brake. Check the plant compressed air supply.
INVERTER FAULT
This error message appears if the microprocessor does not receive
an input from the inverter within 14 seconds of the beginning of
the formula. After 14 seconds without an inverter input, the timer
stops, the basket is stationary, and the drain valve opens. To recov-
er, press the
Next
key (
).
VIBRATION SW TRIPPED
RECOVERY SEQUENCE
When the vibration switch closes, the timer stops. After 45 to 85
seconds, the basket reverses at wash speed as the cylinder fills
with water. When low level is achieved, the cylinder reverses for
one additional minute at wash speed, then accelerates to extract
speed.