2.3.1
How to Avoid Data Loss
BNCJHP02.C02 0000192162 C.2 D.2 A.7 1/2/20 1:16 PM Released
CAUTION:
Avoid Corrupting Formula Data —
Never turn the
Run/Program key-
switch
from the
Program
position to the
Run
position unless the display
says
OK Turn Key to Run
.
�
Failure to follow this direction will result in the loss of all formula
modifications entered during the current programming session. Formulas
not modified during this session will not be affected.
CAUTION:
Avoid Corrupting Configuration Data —
Never shut off machine power,
turn off the
Master switch
, or press the
Emergency Stop button
to exit
the
Program
mode.
�
Once the
Configure
menu has been accessed, all configure decisions
must be confirmed by pressing the
Next button
(
) before another action
can be taken.
�
Failure to follow this direction will result in corruption of machine memory.
Use the following procedures to clear corrupted formula and configuration memory and restore
valid data.
Display or Action
Explanation
CHECKSUM ERROR
This display indicates that all memory will be cleared.
The ma-
chine controller must be reconfigured and any new formulas
or modifications to standard formulas must be re-
programmed.
TURN KEY TO PROGRAM
Accesses the first configuration decision.
LANGUAGE ?
First configure decision.
0=ENGLISH
0
2.3.2
Return to Run Mode (Option 0)
BNCJHP02.C03 0000192161 C.2 D.2 A.7 1/2/20 1:16 PM Released
Option 0
allows for a safe return from the
Program
mode to the
Formula
menu, preserving any
changes that were made during the programming session and maintaining the integrity of pro-
gramming and configuration data.
Display or Action
Explanation
PROGRAM
0
MENU
OK TURN KEY TO RUN
This is
Option 0
of the
Program
menu. From this display, return
to the
Formula
menu or select another available menu option.
Returns to
Run mode
(
Formula
menu)
or
Scrolls the available choices in the
Program
menu.