5-41
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Home
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to find the home (zero) position for a
specified axis. An error will occur if there is no encoder signal at
the time of execution. Home is configured using the HCG
command. This command will jog the stage till it reaches the limit
configured by the HCG command. It will then acquire the zero
position by looking for the index. This command blocks all
communication over the serial port during motion. The controller
will buffer all commands sent during this period and execute them
once the command has found the index. Caution: if you write too
many commands while this command is executing you run the risk
of overloading the receive buffer.
Returns:
A read parameter returns the following calibration values for the
specified axis:
0
–
Not calibrated to home position
1
–
Calibrated to home position
Syntax:
nHOM
–
Standard syntax
nHOM?
–
Returns 1 if homed since last startup otherwise returns 0
0HOM
–
All axes execute home position
Error [#]:
HOM
?
–
Read operation with missing axis number [27]
Parameter
Description:
n[int]
–
Axis number
Parameter
Range:
n
–
0 to 99
Related Commands: HCG
Example:
1HOM
|
Axis 1, Move to home position