5-19
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Configuration Mode
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This setting determines whether the system resolution is calculated
from the LSP, GRR, FSR settings (CFG == 0), or if it is entered directly
by the user (CFG==1).
Returns:
0
–
Resolution is automatically calculated
1
–
Resolution is set manually by the user
Syntax:
nCFGx
–
Standard syntax
nCFG?
–
Read configuration setting
0CFGx
–
Set all axes to configuration x
Error [#]:
CFG
?
–
Read operation with missing axis number [27]
nCFG
–
Missing Configuration parameter [28]
Parameter
Description:
n[int]
–
Axis number
x[int]
–
Configuration Mode
?
–
Read Configuration Mode
Parameter
Range:
n
–
0 to 99
x
–
0 or 1
Related Commands: LSP, GRR, FSR
Example:
1CFG0
|Axis 1, resolution automatic configuration
-
5CFG1
|Axis 5, resolution manual configuration