5-40
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Home Configuration
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to select the direction of motion when the
Home [HOM] command is initialized.
Returns:
A read operation returns the current direction setting:
0
–
Home starts in the direction of the negative limit
1
–
Home starts in the direction of the positive limit
Syntax:
nHCGx
–
Standard syntax
0HCGx
–
A
ll axes set direction
nHCG?
–
Read direction setting
Error [#]:
HCG
?
–
Read operation with missing axis number [27]
nHCG
–
Missing direction setting [28]
Parameter
Description:
n[int]
–
Axis number
x[int]
–
Set direction of motion.
Parameter
Range:
n
–
0 to 99
x
–
0 for setting motion in the direction of the negative limit
1 for setting motion in the direction of the positive limit
Related Commands: HOM
Example:
3HCG0
|
Axis 3, Set initial direction of Home
command towards the negative limit
-
0HCG1
|
All Axes, Set initial direction of Home
command towards the positive limit