5-48
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Positive/ Negative Limit Location
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
Determines orientation of Positive limit, and negative limit.
Returns:
A read operation returns the following limit direction values for the
specified axis:
0
–
Normal orientation
1
–
Reverse orientation
Syntax:
nLDRx
–
Standard syntax
nLDR?
–
Read velocity value
0LDRx
–
Missing axis number, all axes set limit direction
Error [#]:
LDR
?
–
Read operation with missing axis number [27]
nLDR
–
Missing limit parameter [28]
Parameter
Description:
n[int]
–
Axis number
x[int]
–
limit direction value
?
–
Read limit direction value
Parameter
Range:
n
–
0 to 99
x
–
0 or 1
Related Commands:
Example:
1LDR1
|Axis 1, set to reverse orientation
-
5LDR?
|Axis 5, Read limit switch orientation
Содержание MMC-200 Series
Страница 1: ......