5-45
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Jog Acceleration and Deceleration
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to set the desired value for the jog
acceleration and deceleration for a specified axis. The controller
will not allow for JAC values that are greater than AMX.
Returns:
A read operation returns the jog acceleration and deceleration
value in mm/s
2
for the specified axis.
Syntax:
nJACx
–
Standard syntax
0JACx
–
All axes execute acceleration value
nJAC?
–
Read acceleration value
Error [#]:
JAC
?
–
Read operation with missing axis number [27]
nJAC
–
Missing acceleration parameter [28]
Parameter
Description:
n[int]
–
Axis number
x[float]
–
Jog
Acceleration
?
–
Read Jog acceleration value
Parameter
Range:
n
–
0 to 99
x
–
.001 to 500.000 mm/s
2
[degrees/s
2
]
Related Commands: ACC, DEC, AMX
Example:
4JAC0.1
|
Axis 4, Set jog acceleration & deceleration to
0.1 mm/s