5-43
MICRONIX USA, LLC
www.micronixusa.com
Rev: 3.02
Integrator Term Gain
During Motion
Real-time
Program
Global
Set
Read
Set
Read
Set
Read
Set
Read
Command
Description:
This command is used to change the Integrator gain.
iTerm = iTerm/ ITG Lessens the effect of the iTerm. This term is only
used the FBK modes 2 and 3. This feature only available in
firmware version 1.3.1 and higher.
Returns:
The Integrator gain value.
Syntax:
nITGx
–
Standard syntax
Error [#]:
ITG
–
Missing axis number [30]
Parameter
Description:
n[int]
–
Axis number
x[int]
–
Integrator Gain
?
–
Read integrator gain value
Parameter
Range:
n
–
1 to 99
x
–
1 to 5000
Related Commands: IST, IWL, PID, FBK
Example:
2ITG1
|
Axis 2, Set integrator term gain to 1]