Appendix | Control Menu
C-Box/2A
A 3.1.2
Measurement Configuration
Measurement task
Measurement value
sensor 1
Measured value of the sensor connected to connection 1.
Thickness sensor
1-2
Forms the difference between the two distance values of the sensors 1/2 in direct or
diffuse reflection, with two-sided distance measurement, and outputs the result as a
thickness value.
Step sensor 1-2
Forms the difference between the two distance values of the sensors 1/2 in direct or dif-
fuse reflection, with one-sided distance measurement, and outputs the result as height
value.
Mastering/Zeroing
Mastering is dis-
abled
Reset master
value
Value
Cancel zeroing or mastering
Mastering is enabled Set master
value
Value
Trigger zeroing or mastering. Master value range:
-1024 to 1024 mm.
Trigger mode
No triggering
Level triggering
High level / Low level
A continuous output of the measured value is made
as long as the selected level is present. After that
the data output stops
.
Low-Level Logic / High-Level
Logic
Edge triggering
Rising edge /
Falling edge
Value
After the trigger event, the sensor outputs the previ-
ously set number of measured values or starts a
continuous measurement output
.
Low-Level Logic /
High-Level Logic
Software triggering
Value Trig-
ger
now
A measured value output is started as soon as a
software command is triggered. The trigger time is
defined inaccurate. After the trigger event, the sen-
sor outputs the previously set number of readings or
starts a continuous readout