![MICRO-EPSILON C-Box/2A Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/micro-epsilon/c-box-2a/c-box-2a_operating-instructions-manual_1785309050.webp)
Page 50
Setting Controller Parameters
C-Box/2A
6.6.6
Analog Output 1, Analog Output 2
Analog
output 1,
Analog
output 2
Output area
Inactive / 0V ... 5V / -5V ... 5V / -10V ... 10V /
4mA ... 20mA
Specification of analog output,
current or voltage with select-
able value range.
Output signal
Fixed output value / Sensor 1: Measurement
value / Sensor 1: Intensity/ Sensor 1: Shut
-
ter speed / Sensor 1: Reflectivity / Sensor 2:
Measurement value / Sensor 2: Intensity/ Sen
-
sor 2: Shutter speed / Sensor 2: Reflectivity /
C-Box/2A: Measurement value
Specification of analog output,
current or voltage with select-
able value range.
Scaling
Standard scaling
At Standard scaling outputs
the entire measuring range of
the sensor / controller.
Two-point scaling
Start of range
(mm)
Value
The two-point scaling requires
the specification of the begin-
ning and end of the range.
End of range
(mm)
Value
1) Only one measured value can be transmitted.
Fields with a gray
background re-
quire a selection.
Value
Fields with dark
border require the
specification of a
value.
Содержание C-Box/2A