![MICRO-EPSILON C-Box/2A Скачать руководство пользователя страница 76](http://html.mh-extra.com/html/micro-epsilon/c-box-2a/c-box-2a_operating-instructions-manual_1785309076.webp)
Page 76
Appendix | ASCII Communication with Sensor
C-Box/2A
A 2.3.6.6 Data Selection for Ethernet
OUT_ETH NONE|([SENSOR1VALUE][SENSOR1INTENSITY][SENSOR1SHUTTER][SENSOR1REFLEC-
TIVITY][SENSOR2VALUE][SENSOR2INTENSITY][SENSOR2SHUTTER][SENSOR2REFLECTIVITY]
[C-BOXVALUE][C-BOXCOUNTER][C-BOXTIMESTAMP][C-BOXDIGITAL])
Setting the values to be output via Ethernet.
- NONE: No output via Ethernet
- SENSOR1VALUE: Measured value of Sensor 1
- SENSOR1INTENSITY: Intensity of Sensor 1
- SENSOR1SHUTTER: Shutter time of Sensor 1
- SENSOR1REFLECTIVITY: Reflectivity of Sensor 1
- SENSOR2VALUE: Measured value of Sensor 2
- SENSOR2INTENSITY: Intensity of Sensor 2
- SENSOR2SHUTTER: Shutter time of Sensor 2
- SENSOR2REFLECTIVITY: Reflectivity of Sensor 2
- C-BOXVALUE: Calculated value of C-Box
- C-BOXCOUNTER: Counter value of C-Box
- C-BOXTIMESTAMP: Timestamp of C-Box
- C-BOXDIGITAL: Digital inputs/outputs of C-Box
Default = SENSOR1VALUE