![MICRO-EPSILON C-Box/2A Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/micro-epsilon/c-box-2a/c-box-2a_operating-instructions-manual_1785309041.webp)
Page 41
Setting Controller Parameters
C-Box/2A
6.5
Processing
On the
Settings
tab, switch to the
Data recording
menu.
6.5.1
Filter/Averaging
Filter/Averaging
Averaging
No averaging
Measurements are not averaged.
Moving aver-
age
2 / 4 / 8 / 16 / 32 / 64 /
128 / 256 / 512
About the selectable filter width N
of consecutive measured values
the arithmetic mean Mgl is formed
and output. Each new reading is
added and the first (oldest) read-
ing removed from the averaging.
Recursive
average
2 / 4 / 8 / 16 / 32 / 64 /
128 / 256 / 512 / 1024
/ 2048 / 4096 / 8192 /
16384 / 32768
Each new metric MW (n) is
weighted to the (n-1) -fold of the
previous average.
Median filter
3 / 5 / 7 / 9
The median is formed from a
preselected filter width N of mea-
sured values. For this purpose,
the incoming measured values
are re-sorted after each measure-
ment. The mean value is then out-
put as median. If an even value is
selected for the filter width N, then
the middle two metrics are added
together and divided by two.
i
These settings are for the C-Box/2A only. They do not affect the connected sensors.
Fields with a gray
background re-
quire a selection.
Value
Fields with dark
border require the
specification of a
value.
Содержание C-Box/2A