Appendix | ASCII Communication with Sensor
C-Box/2A
A 2.3.6.9 Activate Error Output, Switching Output 2
ERROROUT2 SENSOR1ERROROUT1|SENSOR1ERROROUT2|SENSOR2ERROROUT1|SENSOR2ERROROUT2|S
ENSOR1VALUE|SENSOR1INTENSITY|SENSOR1SHUTTER|SENSOR1REFLECTIVITY|SENSOR2VALUE|SE
NSOR2INTENSITY|SENSOR2SHUTTER|SENSOR2REFLECTIVITY|C-BOXVALUE|LOW|HIGH
Select the signal source for the switching output 2 (to the periphery).
The first four switches only one error output of the sensors.
The next nine monitoring values from the sensors or the C-Box.
The last two switch the output to a level by command.
Default = LOW
A 2.3.6.10 Limit Values
ERRORLIMIT1 <Lower Limit><Upper Limit>
If a measured value respectively calculated value is to be monitored using ERROROUT1, the limits can be set
here.
The minimum and maximum measured value is processed with four decimal places.
ERRORLIMIT2 <Lower Limit><Lower limit>
If a measured value respectively calculated value is to be monitored using ERROROUT2, the limits can be set
here.
The minimum and maximum measured value is processed with four decimal places.
Default = 0.0 0.0