Appendix | ASCII Communication with Sensor
C-Box/2A
A 2.3.2.2 Trigger Level
TRIGGERLEVEL HIGH|LOW LLL|HLL
Sets the active level logic and the switching threshold for the trigger input.
- HIGH|LOW: active level logic
- LLL|HLL: Switching threshold
LLL = High level logic ==> LO = 0..0.7 Volt, HI = 8..30 Volt)
HLL = High level logic ==> LO = 0..3 Volt, HI = 8..30 Volt)
Default = HIGH LLL
A 2.3.2.3 Number of Measuring Values Displayed
TRIGGERCOUNT 0|1...16382|INFINITE|16383
Determines how many measuring values are output after a trigger event.
- 1...16382: Number of measuring values which are displayed after trigger event
- INFINITE|16383: Start the continuous measuring value output after a trigger event
- 0: Stops the continuous output of measuring values
Default = 1
A 2.3.2.4 Software Trigger Pulse
TRIGGERSW
Generating a software trigger. Is the trigger selection is not SOFTWARE, the error message „E43 triggermode
SOFTWARE disabled“ is output.
If the command is resent with active measuring value output, the trigger is stopped and the measuring value
output is finished.