![MICRO-EPSILON C-Box/2A Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/micro-epsilon/c-box-2a/c-box-2a_operating-instructions-manual_1785309036.webp)
Page 36
Setting Controller Parameters
C-Box/2A
Application tips
- The measurement value curve is not smoothed
to a great extent, used to eliminate spikes
- Suppresses individual interference pulses
- In short, strong signal peaks (spikes)
- Also suitable for edge jumps (only minor influ-
ence)
- For rough, dusty or dirty environment, to elimi-
nate dirt or roughness
- Further averaging can be used after the median
filter
Signal without averaging
Signal with averaging
Fig. 15 Median, N = 7
Measured value
Measured value
Position value
Position value
Fig. 16 Original profile
Fig. 17 Profile with Median, N = 9