Wall formwork
Mammut 350
Column formwork – With column panels and access platform
Assembly of the access ladder
The ladder is always installed while
the column panel unit is lying flat
on the ground.
1. Screw the safety cage to the top
end of the ladder (Fig. 58.1).
2. Attach the ladder fixture with
a flange screw 18 to the panel’s
multi-function profile (Fig. 58.2).
3. Hang the pre-assembled ladder
onto the access platform. Make
sure the safety flaps are completely
engaged (Fig. 58.4 Detail).
4. Loosen the clamping angle and
attach the ladder to the ladder
fixture.
5. Screw the clamping angle firmly
to the ladder fixture (Figures 58.3
and 58.5).
Extension ladders
These are required when the
access platform cannot be
accessed with only one ladder
due to the formwork’s height.
The extension ladders are hooked
onto the basic ladders. In addition,
an additional ladder fixture must
be attached to the lower end of
the column formwork. See page
M350-59 for the number of
ladders, ladder fixtures and safety
cages required.
Fig. 58.1
Ladder fixture 33/45
Flange screw 18
Clamping angle
Fig. 58.2
Description
Ref. No.
Ladder 348 ...........................
29-414-50
Ladder 318 ...........................
29-414-55
Safety cage 210 ....................
29-414-85
Safety cage 85 ......................
29-414-90
Safety cage 40 ......................
29-416-90
Extension ladder 210 ............
29-414-60
Ladder fixture 33/45 .............
29-404-35
Flange screw 18 ....................
29-401-10
Fig. 58.3
Fig. 58.4 Detail
Fig. 58.5
M350-58