Wall formwork
Mammut 350
Column formwork – With column panels and access platform
The column panels (Fig. 54.1)
can be used to pour columns
with a side length of up to
105 cm.
The column panel is 125 cm
wide and available in heights
350, 300, 250 and 125 cm.
The perforated profile (Fig. 54.3
is used to precisely set column
cross sections in increments of
5 cm up to a maximum cross sec-
tion of 105 cm by 105 cm.
The alkus facing is not perforated
and thus results in a smooth
concrete surface. The required tie
holes need to be pre-drilled using
a 25 mm diameter drill.
When pouring, do not exceed
the admissible fresh-concrete
pressure of 100 kN/m².
Also observe DIN 18218 for
fresh-concrete pressure and
DIN 4235 for compacting con-
crete with a vibrator.
Description
Ref. No.
M 350 column panel
350/125 AL ...........................
23-005-96
300/125 AL ...........................
23-006-96
250/125 AL ...........................
23-007-96
125/125 AL ...........................
23-008-96
Tensioning screw M 350 .......
29-402-97
Flange nut 100 .....................
29-900-20
Articulated flange nut
15/120..................................
29-900-10
Fig. 54.1
M 350 column panel 350 x 125 AL
Fig. 54.3 Perforated profile
Perforated
profile
Holes for tensioning screws
Holes for tensioning screws
Transport hole
Perforated
profile
6.5 5 5 5
5 5 5 6.5
125
Transport hole
M350-54
Technical Instruction Manual / Status November 2018