Wall formwork
Mammut 350
Column formwork – With standard panels and outside corners
Number of M assembly locks
required for the horizontal
joints of all standard panels:
Æ
4 for panel width 125 cm
Æ
3 for panel width 100 cm
Æ
2 for panel widths below
100 cm
Fig. 53.2
Fig. 53.3
Fig. 53.4
Table 53.1
Columns with a maximum side
length of 100 cm and a pouring
height below 425 cm (Fig. 53.3)
can be formed using standard
panels and outside corners
(Fig. 53.2).
Columns with a side length
exceeding 100 cm and a mini-
mum height of 425 cm require
additional stabilisation with
M alignment rails and tie rods
DW 15. Refer to Table 53.1
to determine the number of
alignment rails and M assembly
locks for required stabilisation,
depending on the pouring height
and the column side length.
Each alignment rail must be
attached to the panel with two
flange nuts 18. Ensure that
alignment rails are attached to
all multi-function profiles all
around the column, starting at
the lowest multi-function profile
(Fig. 53.4). Also observe DIN
18218 for fresh-concrete pres-
sure and DIN 4235 for compact-
ing concrete with a vibrator.
Pouring height
[cm]
Number of alignment rails
(from bottom to top)
Number
of M
assembly
locks
Column side length [cm]
25
50
75
100
125
125
—
—
—
—
—
3
250
—
—
—
—
—
5
300
—
—
—
—
—
6
350
—
—
—
—
—
7
425
—
—
—
—
1
10
475
—
—
—
1
1
10
500
—
—
—
1
1
10
550
—
—
—
1
1
11
600
—
—
—
2
2
12
650
—
—
1
2
2
13
700
1
1
1
2
2
14
750
1
1
1
2
2
15
800
1
1
1
2
2
16
850
2
2
2
3
3
17
900
2
2
2
3
3
18
950
2
2
2
3
3
19
Height 350
Height 700
M350-53