9 LTOS7 Management and Monitoring
V1/V2 Parameter
Read Community:
The read community is only used for SNMP versions V1 and V2. It is like a user id or password that al-
lows access to the LANTIME SNMP objects. The SNMP Monitoring system sends the read community string
along with all SNMP requests. If the community string is correct, the LANTIME responds with the requested
information. If the community string is incorrect, the LANTIME simply discards the request and does not respond.
Write Community:
The write community is only used for SNMP versions V1 and V2. It is like a user id or password that allows
access to the LANTIME SNMP objects. The SNMP Monitoring system sends the write community string along
with all SNMP-SET commands. If the community string is correct, the SNMP-SET command is executed. If
the community string is incorrect, the SNMP-SET command is not executed.
V3 Parameter
Security Name:
SNMP V3 User name
Security Level:
Messages can be sent unauthenticated, authenticated, or authenticated and encrypted by setting the Security
Level to use:
noAuthnoPriv – unauthenticated and unencrypted
authNoPriv – authenticated and unencrypted
authPriv – authenticated and encrypted
Engine ID:
Within an administrative domain, a SNMP V3 Engine ID is an unique identifier of an SNMP engine. A string
with a maximum of 27 characters can be entered here. The string is used to generate the hex engineID by using
the text format scheme described in RFC3411. If for example the string "hello" is configured as engineID, the
generated hex engineID would be 800015dd0468656c6c6f
•
15dd is the hexadecimal representation of the Meinberg enterprise ID 5597
•
04 is an indicator that the text format scheme is used to generate the engine ID
•
68656c6c6f is the hexadecimal representation of the string "hello"
LANTIME CPU Expansion Shelf
Date: 2nd July 2020