Sheeter SVC 525C
159
Maintenance
Maintenance
9.4.7
Checking the vacuum pump VT 4.25
Prerequisites
These prerequisites must be fulfilled:
• Main switch is switched off and secured against accidently switching on
again.
• The fan wheel is stationary.
Maintenance intervals specified by Becker:
Every 3000 operating hours (every 1.5 operating years).
Check the length of the carbon vanes.
Does the length of the carbon vanes come below the prescribed value
of A
MIN
the carbon vanes must be replaced.
The carbon vanes are checked.
Manufacturer
Designation
Type
MBO part number
Use
Company Becker
Vacuum pump
VT 4.25
0104261
Retaining of the cut-
ted chip-out at the
upper cutting cylin-
der.
•
The carbon vanes of the vacuum pump are wearing during produc-
tion.
•
Therefore the length of the carbon vanes must be checked every
3000 operating hours.
•
Does the length of the carbon vanes come below the prescribed val-
ue of A
MIN
the carbon vanes must be replaced.
•
Before checking and replacing the carbon vanes read and under-
stand the operating manual from Becker.
Operating manual vacuum pump VT 4.40
(oi_vt_4.40_01.2013.pdf