Page 85 P/N 03521015 Rev U1
Bio-Medical Devices Intl
17171 Daimler Street Irvine, CA 92614 800-443-3842 www.maxair-systems.com
22. HE DLC Hood with Heavy Loading Filter (HLF)
O.N. 2270-04SM*
(07831036)
Small-Medium
O.N. 2270-04ML*
(07831037)
Medium-Large
*one 2170-26 (07831040) HLF
is included with each Hood
Use only if package is received unopened and contents are
undamaged. If damage is noted, contact the shipper for replacement
or repair.
Prior to using any MAXAIR
®
System or component, be sure to be
familiar with the system’s NIOSH approved configuration.
DO NOT use if any component is damaged. If any components are
damaged or contaminated and therefore unfit for safe and effective
use, they should be replaced immediately.
Only trained and experienced personnel who have read and under-
stand the User’s Instructions should use this product.
Failure to follow the User’s Instructions, these and in the MAXAIR
Systems User’s Instructions, P/N 03521015, may be hazardous to
the user’s health.
The institution using this product in any application is responsible for
determining the appropriateness of this equipment relative to regula-
tory requirements. Bio-Medical Devices Intl, Inc. does not recom-
mend the appropriate systems for a particular institution or facility.
Use only MAXAIR Systems/ NIOSH approved compatible
components.
NOT for use in atmospheres immediately dangerous to life or health
(IDLH), and atmospheres containing less than 19.5% oxygen, or
more than 25% oxygen.
Flammability Level I: fabric may burn if exposed to open flame.
Follow current local regulations governing biohazard waste to safely
dispose of used shrouds.
If you need more information, contact your BMDI Sales
Representative, or call BMDI customer service at 1-800-443-3842.
Symbol Definitions
Warning, Caution, or Note Fluid Resistance
Order Number Part Number
O.N.
PN
Intended Use
The MAXAIR
®
CAPR
®
Hood Systems are intended to filter
aerosolized and droplet particulates and provide high level fluid
resistance.
Hoods are designed for single use applications.
For Use With
The MAXAIR 2270-04 HE DLC Hood is a component of the
MAXAIR CAPR Hood Systems and provides optimum performance
when donned with a MAXAIR CAPR Powered Air Purifying Respirator
(PAPR) 2081-03 Helmet (optionally with 2082-03 Helmet w/chin bar).
CAPR 2270-04 HE DLC Hood
Standard System Configuration
1. 2081-03 Helmet w/ Power Cord 4. 2270-04 HE DLC Hood
2. 2500-36TSC Battery
5. 2170-26 Heavy Loading
Filter
3. 2000-76 Battery Belt
6. 2600-01 Battery Charger
* The 2500-30TSC 16-20 hour/charge battery is an alternate that may be used
in place of the 2500-36TSC.
Materials
MATERIAL
TYPE
FLUID RESISTANCE*
Body (Shroud) Polypropylene
Level 4 compatible
(seams included)
Lens
Polycarbonate
Level 4 compatible
Filter
Polypropylene
Level 3 compatible
HLF
Polypropylene/
modacrylic blend
General purpose fluid
absorption and large
particle filter.
* Internal test data demonstrates material compatibility with the liquid barrier
performance classification levels described in ANSI/AAMI PB 70:2012 for
isolation gowns, etc. Seams between non-like material are excluded.
Specifications
Temperature Limits: 49
0
C
APF = 25
Regulatory
NIOSH
1
2
4
5
6
3
WARNING