Page 91 P/N 03521015 Rev U1
Bio-Medical Devices Intl
17171 Daimler Street Irvine, CA 92614 800-443-3842 www.maxair-systems.com
24. HE Hood with Heavy Loading Filter (HLF)
O.N. 2270-06SM*
(07831038)
Small-Medium
O.N. 2270-06ML*
(07831039)
Medium-Large
*one 2170-26 (07831040) HLF is
included with each Hood
WARNING
Use only if package is received unopened and contents are
undamaged. If damage is noted, contact the shipper for replacement
or repair.
Prior to using any MAXAIR
®
System or component, be sure to be
familiar with the system’s NIOSH approved configuration.
DO NOT use if any component is damaged. If any components are
damaged or contaminated and therefore unfit for safe and effective
use, they should be replaced immediately.
Only trained and experienced personnel who have read and under-
stand the User’s Instructions should use this product.
Failure to follow the User’s Instructions, these and in the MAXAIR
Systems User’s Instructions, P/N 03521015, may be hazardous to
the user’s health.
The institution using this product in any application is responsible for
determining the appropriateness of this equipment relative to regula-
tory requirements. Bio-Medical Devices Intl, Inc. does not recom-
mend the appropriate systems for a particular institution or facility.
Use only MAXAIR Systems/ NIOSH approved compatible
components.
NOT for use in atmospheres immediately dangerous to life or health
(IDLH), and atmospheres containing less than 19.5% oxygen, or
more than 25% oxygen.
Flammability Level I: fabric may burn if exposed to open flame.
Follow current local regulations governing biohazard waste to safely
dispose of used shrouds.
If you need more information, contact your BMDI Sales
Representative, or call BMDI customer service at 1-800-443-3842.
Symbol Definitions
Warning, Caution, or Note Fluid Resistance
Order Number Part Number
O.N.
PN
Intended Use
The MAXAIR
®
Hood Systems are intended to filter aerosolized and
droplet particulates and provide high level fluid resistance.
Hoods are designed for single use applications.
For Use With
The MAXAIR 2270-06 HE Hood is a component of the
MAXAIR Hood Systems and provides optimum performance when
donned with a MAXAIR Systems CAPR 2082-03 Helmet or,
alternatively, with a MAXAIR Systems 2026-03 Helmet.
CAPR 2270-06 HE Hood Standard System
Configuration (showing alternate Helmets, 1 or 2)
1. 2082-03 Helmet w/ Power Cord
and Chin Bar
5. 2500-36TSC Battery
2. 2026-03 Helmet w/Power Cord
and ChinBar
6. 2600-01 Charger
3. 2367-02 Quick Cuff
7. 2270-06 HE Hood
4. 2000-76 Battery Belt
8. 2170-26 Heavy Loading Filter
* The 2500-30TSC 16-20 hour/charge battery is an alternate that
may be used in place of the 2500-36TSC.
Materials
MATERIAL
TYPE
FLUID RESISTANCE*
Body (Shroud) Polypropylene
Level 4 compatible
(seams included)
Lens
Polycarbonate
Level 4 compatible
Filter
Polypropylene
Level 3 compatible
HLF
Polypropylene/
modacrylic blend
General purpose fluid
absorption and large
particle filter.
* Internal test data demonstrates material compatibility with the liquid
barrier performance classification levels described in ANSI/AAMI PB70:2012
for isolation gowns, etc. Seams between non-like material are excluded.
Specifications
Temperature Limits: 49
0
C
APF = 25
Regulatory
NIOSH
2
4
1
5
7
3
6
8