10.0 Using the ME-RTR Router
METER: 03A AGS Status Menu
This read-only menu displays the AGSs current status. There are 26 differ-
ent status messages to identify what state the AGS is currently in only one
displays at any one time (refer also to Figure 10-2).
METER: 03B DC Volts-AGS Menu
This read-only menu displays the DC voltage measured at Terminals #3 and
#4 of the AGS module. This menu is useful in setting up the voltage start for
the AGS, and for troubleshooting its operation.
Info:
The DC voltage reading in this menu may vary from the DC
voltage readings in the METER buttons
01A DC Volts
and
04C DC
Volts-BMK
menus. When troubleshooting, read the appropriate re-
lated meter for each device. When troubleshooting the AGS, use the
03B DC Volts-AGS
menu for veri
cation and testing purposes.
Available statuses are (see Tables 11-1 thru 11-3 for information on each):
Info:
This menu is important when determining if the AGS is work-
ing correctly, or for troubleshooting an AGS installation. For any
fault mode displayed in the status menu, refer to Section 12.0 in
this manual.
METER: 03C Gen Run Time Menu
This read-only menu displays the length of time the generator has been
running since it was autostarted by the AGS. This is useful when trying to
determine how long the generator has been running since it was autostarted
in case you were not present when it started. This menu is enabled when
the
CTRL: 03 Gen Control
menu is set to
AUTO
, but does not display run
time when the generator has been manually started. Cooldown and warm-up
times are not included in this gen run time display.
AC In
Gen Cooldown
Gen Warm-up
Manual Run
No Comm
Off
Quiet Time
Ready
Start Amp
Start Exercise
Start SOC
Start Temp
Start Test
Start Time
Start Topoff
Start VDC
Gen Run Fault
Fault Amp
Fault Exercise
Fault MaxRn
Fault SOC
Fault Temp
Fault Test
Fault Time
Fault Topoff
Fault VDC
Info:
The
Gen Run Time
menus timer is started when the gen run
sense voltage/signal is correct and quali
ed at the AGS module. It is
not considered quali
ed until after a full start attempt and the
Gen
Warm-up Time
setting is satis
ed. Cooldown and warm-up times are
not included in the gen run time display. Total generator run time =
Gen Run Time
+
Gen Warm-up Time
+
Gen Cooldown
.
Info:
The times in this display are shown in tenths of an hour (0.0
hrs., 0.1 hrs., etc.,) thus, 0.1 hrs. = 6 minutes.
Info:
The Gen Run Time display resets to 0.0 each time the genera-
tor is autostopped. This meter is not designed to replace the hour
meter for total hours the generator has run.