10.0 Using the ME-RTR Router
1 DC Meters
2 AC Meters
3 AGS Meters
All Select Meter
PORT, CTRL, METER, SETUP, and TECH Buttons
PORT
CTRL
METER SETUP TECH
Figure 10-1, ME-RTR’s AGS Configuration Access Buttons
10.0 Using the ME-RTR Router
The ME-RTR routers AGS menus under the CTRL, METER, SETUP, and TECH
buttons allow you to customize and monitor operating parameters, and to
help troubleshoot your autostart/autostop generator system. To con
gure and
use the AGS with the ME-RTR, refer to the mini index below to direct you to
the appropriate section.
10.1 ME-AGS-N Setup using the ME-RTR
page 61
10.2 ME-AGS-N Functional Testing using the ME-RTR
page 73
10.3 ME-AGS-N Operation/Monitoring using the ME-RTR
page 75
10.4 Enabling the ME-AGS-N using the ME-RTR
page 78
10.5 Starting and Stopping the Generator using the ME-RTR page 78
10.6 ME-AGS-N Menu Map using the ME-RTR
page 80
Info:
The ME-RTR router used in this section is
Rev. 2.1. Refer to
your routers owners manual to determine your routers revision (or
see Section
10.3.2.3 ME-RTR Routers TECH Button
on page 77).
Info:
The ME-RTR is a multi-inverter remote that allows a single-
inverter remote (ME-RC or ME-ARC) to be connected. When connected
to the ME-RTR, the single-inverter remote acts only as a remote
monitor, but will allow the AGS to be activated. Even though you can
activate the AGS with a ME-RC or ME-ARC connected to the ME-RTR,
the AGSs autostart/autostop settings are obtained from the ME-RTR.
10.1 ME-AGS-N Setup using the ME-RTR
To access the AGS SETUP menus, press and hold the METER button (~3 sec-
onds) to display the System Home screen. From the System Home screen,
press the PORT button, or rotate the SELECT knob to the port# where the
AGS is connected (AGS Home screen), and then press the SETUP button.
The menus available from this screen allow the generator to be automati-
cally started and stopped based on many different conditions. From Table
10-1, determine the speci
c autostart and autostop conditions with which
you want to control the generator.
Info:
For information on using the PORT, CTRL, METER, and TECH
button menus to operate and monitor the AGS, refer to Section 10.3
ME-AGS-N Operation/Monitoring using the ME-RTR.