9
© 2012 Magnum Energy, Inc.
2.0 Installation
2.4.3 Cable Connections with Multiple Devices
If you are using more than one Magnum networked device, a 4-wire phone
splitter is required to connect the devices. There are two options for inter-
connecting the devices either in a Star or Daisy Chain con
guration.
Info:
Before deciding on which con
guration to use, review the dif-
ferences in installation and ease of troubleshooting.
• Star Confi guration
In this arrangement, all the network devices con-
nect to the inverters Network port via a phone splitter, using individual
cable runs (Figure 2-7). Since each device is independently connected
to the inverters Magnum Net or Network port, problems in a cable or
a device can be easily isolated; and, if there is a cable failure to one
device it does not bring down all the devices.
DC 12.6V 5A
SELECT
TECH
AGS
METER
SETUP
SHORE
INVERTER
CHARGER
INV
CHG
FAULT
PWR
ON/OFF
ON/OFF
ME-BMK
Remote Control
ME-AGS-N
Magnum Inverter/Charger
Phone splitter
Figure 2-7, Multiple Network Devices – Star Confi guration
• Daisy Chain Confi guration
In this arrangement, the network de-
vices are linked in a series (Figure 2-8). If using this con
guration, the
ME-AGS-N must be the
rst device connected to the inverters Magnum
Net or Network port followed by the second network device.
DC 12.6V 5A
SELECT
TECH
AGS
METER
SETUP
SHORE
INVERTER
CHARGER
INV
CHG
FAULT
PWR
ON/OFF
ON/OFF
ME-AGS-N (1
st
device)
Remote Control
Magnum Inverter/Charger
Phone
splitter
ME-BMK (2
nd
device)
Figure 2-8, Multiple Network Devices – Daisy Chain Confi guration
Содержание ME-AGS-N
Страница 22: ...2 0 Installation 2012 Magnum Energy Inc 16 Figure 2 13 Two wire Control Type Generators ...
Страница 23: ...17 2012 Magnum Energy Inc 2 0 Installation Figure 2 14 Three wire Momentary Control Type Generators ...