65
Parameter
Name
Description
Setting Range
Action after Switch If a Run command at the new source is active, the
drive will not start or the drive will stop operation
if it was running when switching from the old
source to the new source. The drive can start only
when the Run command is removed and given
again.
1
∶
Accept Active Run Command at the New
Source
If a run command at the new source is active, the
drive will accept it and run the motor immediately
right after switching from the old source to the
new source.
Min.: 0
Max.: 1
b1-06
Run Command
Selection during
Programming
0
∶
Run command disabled during Programming
1
∶
Run command enabled during Programming
2
∶
Prohibit programming during run
The programming mode cannot be displayed
during run except for monitoring parameter
Group U.
Default
∶
0
Min.: 0
Max.: 2
b1-07
Frequency
Command Selection
2
Enabled while E1-00 to E1-07 is set to 4 and the
DIP switch is set to OFF
0
∶
Keypad
1
∶
Control Circuit Terminal (Analog Input)
2
∶
Terminal Up/Down
3
∶
Modbus Communication
4
∶
Pulse Train Input (Including PWM signal input)
5: Expansion card
Default
∶
0
Min.: 0
Max.: 6
b1-08
Run Command
Selection 2
Enabled while E1-00 to E1-07 is set to 4 and the
DIP switch is set to OFF
0
∶
Keypad
1
∶
Control Circuit Terminal (Sequence Control
Input)
2
∶
Modbus Communication
3
∶ Expansion card
Default
∶
0
Min.: 0
Max.: 3
b1-09
<7>
Frequency
command
superposition
selection
0: Invalid
1: Valid
Default
∶
0
Min.: 0
Max.: 1
b1-10
Run Command at
Power up
Determines to accept or ignore an active Run
command from Remote during power up.
0
∶
Ignore
Drive ignores an active run command during
Default
∶
0
Min.: 0
Max.: 1
Содержание EVO 8000 Series
Страница 1: ......
Страница 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Страница 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Страница 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Страница 49: ...46 4 3 2 2 Pulse input wiring diagram...
Страница 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Страница 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...