39
4.2.3 Main Circuit Cable Size and Tightening Torque
Select the cables and crimp terminals according to Table 4.2.2.
1. The recommended cable size is based on Normal Duty Mode using 75 °C 600 V vinyl-sheathed
cable with ambient temperature tolerance below 40 °C and wiring distance less than 100 m.
2. Te1, +2, B1, B2 are only for connecting DC reactor and braking resistor options. Do not
connect other devices.
3. Consider the amount of voltage drop when selecting cable sizes. Increase the cable size when the
voltage drop exceeds 2% of the motor rated voltage. The amount of voltage drop can be calculated
using the following formula:
Line drop voltage (V) = 3 × cable resistance (Ω/km) × cable length (m) × current (A) × 10
-3
Table 4.2.2 Cable Size and Tightening Torque (Three-phase 400 V)
Drive
Rating
Terminal
Asia
USA
Europe & China
Terminal
Screw
Size
Tightening
Torque
Nm ( lb.in.)
Suggested
Cable Size
mm2
Applicable
Cable Size
mm2
Suggested
Cable Size
AWG,
kcmil
Applicable
Cable Size
AWG,
kcmil
Suggested
Cable Size
mm2
Applicable
Cable Size
mm2
0.75kW~
2.2kW
DC-,DC+1,DC+2,B1,B2,
GND,R/L1,S/L2,T/L3,U/
T1,V/T2,W/T3,PE
5.3
0.8 ~ 5.3
10
18 ~ 10
5.3
0.8 ~ 5.3
M4
1.97
(
17.4
)
3.7kW ~
5.5kW
DC-,DC+1,DC+2,B1,B2,
GND,R/L1,S/L2,T/L3,U/
T1,V/T2,W/T3,PE
5.3
0.8 ~ 5.3
10
18 ~ 10
5.3
0.8 ~ 5.3
M4
1.97
(
17.4
)
7.5kW ~
15kW
DC-,DC+1,DC+2,B1,B2,
GND,R/L1,S/L2,T/L3,U/
T1,V/T2,W/T3,PE
13.3
13.3~ 5.3
6
10 ~ 6
13.3
5.3~13.3
M5
3.73
(33)
18.5kW ~
30kW
DC-,DC+1,DC+2,B1,B2,
GND,R/L1,S/L2,T/L3,U/
T1,V/T2,W/T3,PE
53.5
53.5~8.4
8
1/0 - 8
53.5
53.5~8.4
M8
8.83
(78.2)
37kW
~
55kW
R/L1,S/L2,T/L3,P,DC+,D
C-,U/T1,V/T2,W/T3
107.2
107.2~8.
4
8
4/0-8
107.2
107.2~8.
4
M8
14.7
(130)
75kW
~
110kW
R/L1,S/L2,T/L3,P,DC+,D
C-,U/T1,V/T2,W/T3
202.7 202.7-8.4
8
400-8
202.7
202.7-8.4
M8
14.7
(130)
Содержание EVO 8000 Series
Страница 1: ......
Страница 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Страница 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Страница 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Страница 49: ...46 4 3 2 2 Pulse input wiring diagram...
Страница 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Страница 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...