26
Chapter 3│Drive Installation
3.1 Installation Environment
To ensure the optimum drive performance, install the AC drive in a proper environment specified
below.
Environment
Conditions
Area of Use
Indoors
Ambient
Temperature
-10°C to +40°C (IP20/NEMA 1 enclosure)
-10°C to +50°C (IP00 enclosure)
Do not install the drive in environments with wide temperature fluctuations so
as to ensure the drive reliability.
When the drive is installed in an enclosure cabinet, make sure the cooling
works properly to keep the temperature within the specified levels.
Do not allow the drive to freeze.
When drives are installed side-by-side in a cabinet, follow the instruction
illustrated in Figure 3.2 to ensure the air flow.
Humidity
Under 95% RH
Free of condensation
Storage
Temperature
-20°C to +60°C
Surrounding
Area
Free from water, oil, metal shavings or other foreign materials.
Free from flammable materials (e.g., wood)
Free from harmful gases and liquids
Free from direct sunlight
Free from oil mist, corrosive gas, flammable gas or dust.
Free from radioactive material
Green Class 2 or above
Altitude
Up to 1000 m without derating. Up to 2000 meters with 1% rated current derated
for every 100 m counted from 1000 m.
Vibration
10 to 20 Hz at 9.8 m/s2
20 to 55 Hz at 5.9 m/s2 (2A0004 to 2A0211, 4A0002 to 4A0165) , or 2.0 m/s2
(2A0250 to 2A0415, 4A0208 to 4A1200)
Enclosure
IP20/NEMA 1.
Содержание EVO 8000 Series
Страница 1: ......
Страница 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Страница 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Страница 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Страница 49: ...46 4 3 2 2 Pulse input wiring diagram...
Страница 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Страница 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...