97
Parameter
Name
Description
Setting Range
P2-04
KEB Deceleration
Time
Sets the time to decelerate during KEB function.
Default: 0.0 s
Min.: 0.0 s
Max.: 6000.0 s
P2-05
Acceleration Time
after KEB
Sets the time to reaccelerate from the speed
when KEB function was deactivated to the set
frequency command (operation frequency before
power loss).
When set to 0.0 s, the drive will accelerate to the
previously active frequency according to the
active acceleration time set by any of C1-00,
C1-02, C1-04 or C1-06.
Default: 0.3 s
Min.: 0.0 s
Max.: 6000.0s
P2-06
<7>
Emergency stop
setting level before
power failure
By setting the P2-06 level, when the voltage level
is detected to be lower than P2-06, the inverter
will decelerate according to the C1-08 emergency
stop time until it is lower than the P2-03 UV
detection value.
According to the
model, the 200V model
is 150~280, and the
400V model is
300~560.
P2-07
KEB Detection Time
Sets the minimum duration of KEB operation after
activation.
KEB function will operate according to this
detection time even if power recovers within this
duration.
Default: 50 ms
Min.: 0 ms
Max.: 2000 ms
P2-08
Voltage Target
During KEB
Sets the target value for the main circuit DC
voltage or to deactivate KEB.
Default: Depending on
d1-00
D1-00 is greater than
400V for 500V, less
than 400V for 460V
P2-09
KEB Method
Selection
0 : KEB Operation Method 1
1 : KEB Operation Method 2
2 : KEB Operation Method 3
Default: 0
Range: 0, 1, 2
P2-10
AVR Selection
0 : Disabled
1 : Enabled
Default: 1
Range: 0, 1
P2-11
<7>
Emergency stop
action selection
before power
failure
0: Invalid
1: Valid
Default: 0
Range: 0 to 1
P3: Stall Prevention
P3-00
Stall Prevention
during Acceleration
0
∶
Disabled
1
∶
Enabled the value set in P3-01.
Acceleration stops when the output current
exceeds the value set in P3-01. Acceleration
Default: 1
Range: 0, 1
Содержание EVO 8000 Series
Страница 1: ......
Страница 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Страница 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Страница 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Страница 49: ...46 4 3 2 2 Pulse input wiring diagram...
Страница 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...
Страница 169: ...166 22F 392 Ruey Kung Road Neihu Taipei City 114 Taiwan...