107
Parameter
Name
Description
Setting Range
t1-10
Target frequency
during inertia
estimation
Sets the target frequency of rotation during the
inertia estimation
Default
∶
50Hz
Min.: 0
Max.: 60Hz
t1-11
Rated torque during
inertia estimation
Sets the rated torque for rotation during the
inertia estimation
Default
∶
50%
Min.: 0
Max.: 100%
t1-12
Motor Auto-Tuning
Setting
Enables or disables Auto-Tuning when A1-02=0 to
3
0 : Disabled
1 : Enabled
Default
∶
0
Min.: 0
Max.: 1
t2: PM Motor Auto-Tuning
t2-00
PM Motor
Auto-Tuning
Method Selection
0
∶
PM Rotational Auto-Tuning
1
∶
PM Stationary Auto-Tuning
2
∶
PM offset angle Auto-Tuning for resolver card
3
∶
PM offset angle Auto-Tuning for resolver card
· Perform Auto-Tuning.
· Set the correct value according to the test report
or motor nameplate.
Default
∶
0
Min.: 0
Max.: 3
t2-01
Initial current for
initial position
detection
Sets the current value of the PM motor for initial
position detection
Default: 30%
Min.: 30%
Max.: 100%
t2-02
PM Motor Type
Selection
0
∶
IPM Motor
1
∶
SPM Motor
Default: 1
Range: 0, 1
t2-03
PM Motor Output
Power
Sets the PM motor rated output power in kW
units.
Note: 1HP (Horse Power) = 0.746kW
Default: Determined by
o2-03
Min.: 0.00 kW
Max.: 650.00 kW
t2-04
PM Motor Rated
Voltage
Sets the PM motor rated voltage according to the
motor nameplate.
Default: 200.0 V
Min.: 0.0 V
Max.: 255.0 V <3>
t2-05
PM Motor Rated
Current
Sets the PM motor rated current according to the
motor nameplate.
Default: Default: 50%
of drive rated current
Min.: 10% of drive
rated current
Max.: 200% of drive
rated current
t2-06
PM Motor Base
Frequency
Sets the PM motor base frequency according to
the motor nameplate.
Default: 87.5 Hz
Min.: 0.0 Hz
Max.: 400.0 Hz
t2-07 Number of PM
Sets the number of PM motor poles according to
Default: 6
Содержание EVO 8000 Series
Страница 1: ......
Страница 3: ...7 4 MODBUS Data List 142 APPENDIX UL DESCRIPTION 156...
Страница 15: ...12 2 2 Nameplate Model Number Applicable motor rating Input power supply Output power supply...
Страница 48: ...45 4 3 2 1 Multi Function Digital Input Wiring Diagram...
Страница 49: ...46 4 3 2 2 Pulse input wiring diagram...
Страница 55: ...52 F1 F4 F5 F6 Figure 4 4 4 DIP Switch RS 485 Termination Resistor OFF ON...