- Any output set to AUX 2 Calibration Mode Settings will always be on (Active and
Sinking to ground)
·
On
-
During Active Delivery
- Any output set to AUX 2 Calibration Mode Settings will be
on (Active and
Sinking to ground) when a delivery is active on the LCR.iQ. The output will
be on when a delivery is started and will not turn off until an end of delivery command is
given.
·
On - During Run State
- Any output set to AUX 2 Calibration Mode Settings will be on
(Active and Sinking to ground) when a delivery is active and not paused. The output will be
on when a delivery starts. However, if the delivery is paused by issuing a stop command,
the output will turn off until the resume command is given. If the end of delivery command
is given, the output will remain off and the delivery will end.
·
On - Flow Rate Monitor
- Any output set to AUX 2 Calibration Mode Settings will be on
when a delivery is active. However, it will deactivate if the flow rate meets or exceeds 40
units/time. If the flow rate does not meet or exceed 40 units/time, the output will remain
on.
·
On - Reverse Flow
- Any output set to AUX 2 Calibration Mode Settings will be off when
a delivery is started and will only turn on when the register detects flow in the negative or
reverse direction.
·
Reset Pulse/Delivery Start
- Any output set to AUX 2 Calibration Mode Settings will
output a short pulse at the start of a delivery that is used with 3rd-party remote counters
that require a reset pulse to reset to 0.0.
·
Toggle Flow Rate
- Any output set to AUX 2 Calibration Mode Settings will turn on once
the flow rate of the LCR.iQ exceeds the set flow rate point in the Auxiliary 1 Flow Rate
Toggle field below.
·
Calibrated Scaled Pulse Output
- Any output set to AUX 2 Calibration Mode Settings will
output a calibrated pulse output that is scaled according to the Pulse Output Frequency
setting in the calibration mode.
Auxiliary 2 Flow Rate Toggle
– A numeric text field for programming a flow rate set point,
when the Aux 2 is set to Toggle flow rate. Auxiliary 2 remains activated above the set flow rate
value, and deactivates when the flow rate falls below the value.
Net Totalizer
– A numeric text field that shows the current accumulative net totalizer value of
the current selected product on the LCR.iQ. The Net Totalizer uses a non-resettable totalizer.