LCR.iQ - Setup and Operations Manual
66
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
the register has delivered up to 1 gallon (4 Litres), then this key will disappear from the
onscreen action options.
Fully-packed hose:
To comply with Weights & Measures
requirements, it is necessary to start and stop each delivery with a
fully packed hose. This will be the case with normal deliveries.
However, there are times where the hose is not fully packed (for
example, after a preset delivery). As such, the hose must be packed
and the register zeroed prior to making the next delivery.
Options:
·
Yes
- Hose reset option is active
·
No
- Hose reset option is not active
NOTE:
See
Operating the LCR.iQ
for more detail on using the
hose reset feature.
Register (3/3)