LCR.iQ - Setup and Operations Manual
77
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
Meter ID
– A text field for identifying a meter that is connected to the LCR.iQ, Typically, the
serial number of the meter is entered here. The value of this field is also printed on the LCR.iQ
calibration ticket.
(Maximum - 10 alphanumeric characters)
Pulser Input Type
– A list box for selecting the type of pulse input signal that will be
connected to the selected I/O board.
Options:
·
Dual
Channel
- 2 channel quadrature pulser signal such as the LCR.iQ internal pulser or a
POD pulser.
·
All Single
Channel
- Single channel square wave signal
·
Triple
Channel
- 3 channel pulser square wave signal
·
None
- No pulser is connected to the LCR.iQ
Flow Direction
– A list box field for inverting the direction of flow that is registered by the
LCR.iQ. If the register is counting in the reverse direction when first installed, inverting the flow
direction will cause the register to count in the opposite direction.
Options:
·
==>
·
<==
Pulser Input Between Deliveries
– A list box field for specifying how the LCR.iQ will respond
to any registered pulse signal when the register is not in an active delivery.
Options:
·
Count Forward and Reverse
- A registered pulse signal–either forward or reverse–will
directly affect the accumulative totalizer readings. It will also display the volume on the idle
delivery screen.