adjust the
Pulse/Unit
field by the percent error that is calculated. Learn more in
Single-point
Calibration
.
Linearization Mode
– A list box for applying multi-point calibration, when such calibration is in
use. Setting this field to
Applied
will activate multi-point calibration, if all parameters have been
met for using multi-point calibration. For instructions on how to perform multi-point calibration,
see
Multi-point Calibration
.
Compensation Table
– A list box for selecting and using temperature compensation on a
product that is being set up. See the Compensation Types and Parameter chart below for
details of each table.
Options:
·
None
- Select None if no temperature compensation is to be used
·
Table 24
- Select this table for LPG (USA)
·
Table 54/54E
- Select this table for LPG (Canada and Europe)
·
Table 54B
- Select this table for Refined Petroleum (Canada and Europe)
·
Table 54C
- Select this table for Specialized Products (Canada and Europe)
·
Table 54D
- Select this table for Lube Oil (Canada and Europe)
·
Table 6B
- Select this table for Refined Petroleum (USA)
·
Linear C
- Select this table for a general Linear table when measuring Celsius
·
Linear F
- Select this table for a general Linear table when measuring Fahrenheit
·
NH3
- Select this table for measuring Ammonia (Canada)