LCR.iQ - Setup and Operations Manual
84
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
·
Products 1-16 are available for setup.
Only setup and calibrate products that are to be
used by the LCR.IQ.
Product Type
– A list box for selecting the product (classification) type. The product type will
print on all calibration and diagnostic ticket,s and it will designate the Product Type for each
Product Number. The product type will also appear on all delivery tickets to assist in identifying
the delivered product.
Options:
·
Ammonia
·
Aviation
·
Distillate
·
Gasoline
·
LPG
·
Lube Oil
·
Methanol
·
Blank
Pulses/Unit (Gallon, Liter…)
– A numeric-only text field for specifying the number of pulses
that equal the whole-unit of measure for the product being setup on the LCR.iQ. This number
is most important, since it directly affects the calibration of the meter.
(Maximum setting -
20000.000000 units)
NOTE:
A
chart of starting reference calibration factors
can be
found in an appendix to this manual. Refer to this chart for assistance
in selecting a starting Pulses/Unit number.
Prover Quantity
– A numeric-only text field for calibrating the product currently being set up.
This field is used during calibration to enter the known prover quantity of a volumetric proving
device or master meter. After a calibration run, entering a value into this field will automatically
124
Access the online version of this manual via computer or mobile device at: LCmeter.com/manuals